Specifying 1-Hour and 2-Hour Fire-Resistance-Rated Wall Assemblies

For about a century, architects and builders have used gypsum panels in wall assemblies to meet the criteria for 1- and 2-hour fire-resistance-rated wall assemblies. As product engineering develops, more and more architects are now looking for product solutions that bring added value to their 1-hour and 2-hour fire-resistance-rated wall assemblies.

Many are specifying LP® FlameBlock® Fire-Rated Sheathing because it meets code requirements for fire-resistant construction while potentially providing faster and easier installation than assemblies that use exterior gypsum and structural panels. They can also provide added design flexibility by reducing the overall wall thickness.

Why LP® FlameBlock® Sheathing for Fire-Resistance-Rated Assemblies?

With these design challenges in mind, LP Building Solutions created LP® FlameBlock® Fire-Rated Sheathing for low- and mid-rise wood and light gauge structures. LP FlameBlock sheathing may allow fire-resistance-rated walls to be constructed faster than common alternatives, potentially reducing labor costs while providing exceptional strength, durability and consistency.

UL fire-resistance-rated wall assemblies with LP FlameBlock sheathing provide several benefits to architects, engineers, builders, developers, contractors and even homeowners. LP FlameBlock sheathing wall assemblies provide design flexibility by combining structural capacity and fire resistance in a single panel. It may eliminate a layer of gypsum to help simplify and expedite the construction process. Potential cost savings may allow designers and builders to redirect the funds into design elements their clients are seeking, increasing the value of the property.

Let’s examine how LP FlameBlock sheathing can be used in a few different fire-resistance-rated wall assemblies.

Singe-Family Fire-Resistances-Rated Wall Assemblies

These UL assemblies are commonly used for single-family homes within close proximity of a property line.

UL Design No. V340: This assembly allows for 2x4 wall construction and is fire-resistance-rated for 1 hour from both sides.

v340 1-hour wall assembly

UL Design No. U348 (stucco): This assembly is used with stucco and is fire-resistance-rated for 1 hour from both sides.

 u348 1-hour either side w/ stucco

UL Design No. U348 (brick): This assembly is used with brick and is fire-resistance-rated for 1 hour from both sides.

 u348 1-hour either side w/ brick

Benefits:

  • No exterior gypsum is required
  • Consistent wall thickness with unrated walls

Townhouse Fire-Resistance-Rated Wall Assemblies

These assemblies are typically used in dividing walls in townhouses.

UL Design No. V340 (Two 1-hour walls, back-to-back)

 v340 two 1-hour wall assembly

Benefit:

  • No code restrictions for mechanical, electrical and plumbing.

UL Design No. U350A and U350B (Common 2-hour fire-resistance-rated wall)

 u350A 2-hour either side wall assembly

u350B 2-hour either side wall assembly

Benefits:

  • Alternative to a shaft wall system
  • Uses conventional framing practices
  • Sound Transmission Class (STC) rating of 61

Multifamily Fire-Resistance-Rated Wall Assemblies

UL Design U348: This is commonly used in Type V multifamily construction in load-bearing exterior walls. It also allows for the use of fiberglass insulation. This assembly is fire-resistance-rated for 1 hour from the interior side only, except when brick and stucco is the exterior facing.

u348 1-hour interior resistance only wall assembly

Mid-Rise Wall Assemblies

These assemblies are commonly used for Type III and Type V exterior walls.

UL Design No. V337 (1-hour from either side)

V337 1-hour either side assembly render

UL Design No. V337 (2-hour interior, 1-hour exterior)

V337 2-hour interior, 1-hour exterior wall assembly

UL Design No. V340 (1-hour from either side)

 v340 1-hour either side wall assembly

UL Design No. V340 (2-hour interior, 1-hour exterior)

 v340 2-hour interior, 1-hour exterior wall assembly

When using UL Design No. V340 assemblies for Type III exterior walls, 2-sided LP FlameBlock sheathing is required.

Benefit:

  • No exterior gypsum is required for exterior 1-hour fire-resistance rating

UL Design No. V337 with gypsum and V337 with stucco (2-hour from either side)

v337 2-hour either side wall assembly

Benefits:

  • Potentially reduces the amount of exterior gypsum required
  • Base layer of interior gypsum may be replaced with 2-sided LP FlameBlock sheathing for double-sided shear walls

UL Design No. U349 (2-hour interior)

 u349 2-hour interior wall assembly

UL Design No. U349 (2-hour interior, 1-hour exterior)

u349 2-hour interior, 2-hour exterior wall assembly 

UL Design No. U349 (2-hour from either side)

 u349 2-hour either side w/ brick wall assembly

Benefits:

  • LP FlameBlock sheathing maintains the full strength of the substrate used
  • Some water-resistive coatings may be used in conjunction with LP FlameBlock sheathing

Code compliance does not have to limit design flexibility, budget or schedule. LP FlameBlock Fire-Rated Sheathing assemblies offer code-compliant solutions for a variety of building needs, including numerous UL assemblies for fire-resistance-rated wall systems. The OSB substrate of LP FlameBlock sheathing also has an Exposure 1 classification—which signifies that panels are intended to resist the effects of moisture on structural performance during active construction.

Fire-resistance-rated wall assemblies shouldn’t interfere with your design capabilities and construction schedules. Check out our LP FlameBlock page to learn more about the various assemblies.

Continue Reading

Business Solutions

4 min

Q&A: How Home Orientation Impacts Continuous Insulation

There’s a lot to consider when it comes to building an energy-efficient home for your clients and the many nuances that change with each build—including its orientation to the sun.

Continue Reading

Resiliency Solutions

5 min
HOW A RADIANT BARRIER CAN IMPROVE BURIED DUCT PERFORMANCE

There are several insulation methods based on attic design, but ducts placed over the bottom of truss chords and buried under insulation in a vented attic is a popular builder option.

Sustainability Solutions

8 min
How to Drive Effective Communication and Collaboration on the Jobsite

Every jobsite has a ton of moving parts, from product shipments, supplies, and schedules to subcontractors and homeowners. It's no wonder that many project teams can struggle to maintain quality jobsite communication and collaboration throughout the building process.

Sustainability Solutions

6 min
Carbon Negative, Future Positive: LP® Structural Solutions Portfolio Releases Environmental Product Declarations

In an era where environmental responsibility is paramount, we are proud to announce a remarkable achievement: the LP® Structural Solutions portfolio has been officially designated as carbon negative. This milestone is a testament to our unwavering commitment to redefining construction materials for the better with a focus on sustainability, resiliency and groundbreaking advancements.